Part Number: M27500-14-TE-1-T14
M27500 is low voltage, high temperature cable (shielded or unshielded) that is ideal for use in a variety of both military and commercial applications, including those involving airframes, avionics, and ground support equipment. The M27500 specification allows for a wide range of construction choices, and as a result, it can be manufactured to perform in virtually every type of environment....
Part Number: M27500-14-TE-3-T14
M27500 is low voltage, high temperature cable (shielded or unshielded) that is ideal for use in a variety of both military and commercial applications, including those involving airframes, avionics, and ground support equipment. The M27500 specification allows for a wide range of construction choices, and as a result, it can be manufactured to perform in virtually every type of environment....
Part Number: M27500-14-TE-4-T14
M27500 is low voltage, high temperature cable (shielded or unshielded) that is ideal for use in a variety of both military and commercial applications, including those involving airframes, avionics, and ground support equipment. The M27500 specification allows for a wide range of construction choices, and as a result, it can be manufactured to perform in virtually every type of environment....
Part Number: M27500-14-TG-1-T14
M27500 TG and TH cables are shielded and jacketed cables with extruded ETFE (Ethylene Tetrafluoroethylene) jackets, incorporating MIL-W-22759/18 or /19 wires. These component wires are insulated with thin-wall extruded ETFE for weight and space savings, and have either tin-plated copper or silver-plated high-strength copper alloy conductors. Performance: Voltage...
Part Number: M27500-14-TG-2-T14
M27500 TG and TH cables are shielded and jacketed cables with extruded ETFE (Ethylene Tetrafluoroethylene) jackets, incorporating MIL-W-22759/18 or /19 wires. These component wires are insulated with thin-wall extruded ETFE for weight and space savings, and have either tin-plated copper or silver-plated high-strength copper alloy conductors. Performance: Voltage...
Part Number: M27500-14-TG-4-T14
M27500 TG and TH cables are shielded and jacketed cables with extruded ETFE (Ethylene Tetrafluoroethylene) jackets, incorporating MIL-W-22759/18 or /19 wires. These component wires are insulated with thin-wall extruded ETFE for weight and space savings, and have either tin-plated copper or silver-plated high-strength copper alloy conductors. Performance: Voltage...
Part Number: M81044/12-14-6
SAE AS81044/12 Cable M81044/12-14-2 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-1
SAE AS81044/12 Cable M81044/12-14-0 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-8
SAE AS81044/12 Cable M81044/12-14-2 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-3
SAE AS81044/12 Cable M81044/12-14-2 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-7
SAE AS81044/12 Cable M81044/12-14-2 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-9
SAE AS81044/12 Cable M81044/12-14-9 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-4
SAE AS81044/12 Cable M81044/12-14-2 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-0
SAE AS81044/12 Cable M81044/12-14-0 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-54
SAE AS81044/12 Cable M81044/12-14-54 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-2
SAE AS81044/12 Cable M81044/12-14-2 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M22759/34-14-9
"M22759/34-20-5 Normal Weight Wall Cross-Linked ETFE Wire Insulation: Dual Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/34); Silver Plated High Strength Copper Alloy (/35) Operating Temperature: 150 deg C/200 deg C Operating Voltage: 600 Volts...